Alcohol Biosensor Based on Multi ̄Walled Carbon Nanotubes/Platinum Nanoparticles Nanocomposite

Zhiying MIAO,Chen NIAN,Xueguang SHAO,Qiang CHEN
DOI: https://doi.org/10.3969/j.issn.1004-1699.2017.01.003
2017-01-01
Abstract:MWCNTs ̄PtNPs nano composite was prepared by ultrasonic method,and its modified to ethanol biosensor showed good performance. The experimental results show that the minimum detection limit of the sensor is 0. 02 mmol/L,the linear range is 0.25 mmol/L~3.0 mmol/L,the sensitivity is 0.923 32 μA/(mmol/L),and has high stability and good reproducibility.