Aptamer-based electrochemical detection of thrombin based on chitosan/carbon nanotubes/graphene/nickel hexacyanoferrate nanocomposites

Li-juan Xiao,Juan Sun,Ya-qin Chai
DOI: https://doi.org/10.3969/j.issn.1008-2298.2014.03.009
2014-01-01
Chemical Sensors
Abstract:In this paper, we successfully fabricated a highly sensitive label-free electrochemical aptasensor for thrombin (TB) detection. The nanocomposites composed with chitosan, carbon nanotubes, graphene and nickel hexacyanoferrate (CS-CNTs-Gra-FP) was used as a matrix for thrombin aptamer (TBA) immobilization. The employment of CS-CNTs-Gra-FP nanocomposites and nano-Au not only enhanced the surface area of the electrode with increased FP immobilization, but also enhanced the electron transfer, which further effectively improved the sensitivity of this proposed aptasensor. The resulted aptasensor exhibited good current response to thrombin with a wide linear range extended from 0.01 nmol/L to 30 nmol/L, and the detection limit was 0.003 nmol/L. Furthermore, the prepared aptasensor had great advantages in simplification, rapidity, stability and selectivity.
What problem does this paper attempt to address?