Simultaneous determination of 13-HODE and 9-HODE in cured meat products by normal-phase HPLC

Chun-jiao JIANG,Yu JIANG,Zhi-ming GENG,Hui SONG,Mu-han ZHANG,Dao-ying WANG,Wei-min XU
DOI: https://doi.org/10.13386/j.issn1002-0306.2017.24.052
2017-01-01
Abstract:13-hydroxy-9,11-octadecadienoic acid (13-HODE) and 9-hydroxy-9,11-octadecadienoic acid (9-HODE) in cured meat products were detected with high performance liquid chromatography connected to a diode array detector(HPLC-DAD).The analytes,extracted with methanol and cleaned up by solid phase cleanup with C18 column,were separated on a Lichrosorb Si 60 column (250 x 4.0 mm,5 μm) with a mobile phase consisting of n-hexane/isopropanol/acetic acid (98∶ 2∶ 0.5,v/v/v)in isocratic elution and the detection wavelength was set at 234 nm.The results indicated that 13-HODE and 9-HODE displayed good linearity in the ranges of 0.5~ 20.0 μg/mL (R2 =0.9994) and 1 ~ 12.5 μg/mL (R2 =0.9990),respectively.Limits of detection for 13-HODE and 9-HODE were 0.075 and 0.15 μg/g,respectively,and quantification limits were 0.25 and 0.5 μg/g,respectively.The average recoveries spiked at different levels were 88.2% and 86.0%,respectively.The method was successfully employed to detect the analytes in 14 cured meat products and the results showed that all samples contained 13-HODE and 9-HODE ranging from 1.2~167.54 μg/g and 0.63 ~ 139.20 μg/g,respectively.This method proved to be of high maneuverability as well as excellent sensitivity and accuracy,and could be used for quantitative analysis of 13-HODE and 9-HODE in cured meat samples simultaneously.
What problem does this paper attempt to address?