Application of TESTO Rapid Testing Method on the Quality Monitoring of Repeated Usage of Frying Oil

Shu Zhu,Lihua Song
DOI: https://doi.org/10.3969/j.issn.1003-0174.2017.10.028
2017-01-01
Abstract:Repeated usage of deep frying oil is a general approach in food manufactures and fast food restaurants for cost saving.To use repeated frying oil properly and control the food safety,it is important to monitor the oil qualiy during deep frying.In present study,twelve categories of frying oils were selected as monitoring targes which includes seven single oils and five blending oils products such as soybean oil,palm oil,high oleic acid rapeseed oil,etc.Three products,French fries,chicken nuggets and fish filets,were selected for deep frying test.The total polar components (TPC) in frying oil samples were tested every twelve hours and the correlation between column chromatography and TESTO 270 rapid test results were compared.Our results showed that TESTO 270 method showed significant correla-tion with colunn chromatography method when TPC level was lower than 20% (Pearson correlation coefficient was from 0.744 to 0.984,P < 0.01).But the correlation coefficient was lower when the level of total polar compound (TPC) exceeded 20% (Pearson correlation coefficient was from 0.553 to 0.928,P < 0.01,and R2 =0.149 2 to 0.863 2).The false positive rate was 3.6% when TPC level was between 20% and 27%,and false negative rate was 10% when TPC level was higher than 27%.The results provided the reference data for TESTO 270 rapid testing method in the quality monitoring of repeated usage of deep frying oil.