Simultaneous Detection of Phytosterols and Phytosterol Esters with HPLC

Fuming Yang,Ying Ma
DOI: https://doi.org/10.3969/j.issn.1003-0174.2017.06.023
2017-01-01
Abstract:Simultaneous detection method of phytosterols and phytosterol esters was studied by reversed-phase HPLC.Acetone and acetonitrile(3∶1)was used as mobile phase,12 compounds of phytosterols and phytosterol esters could be separated completely under the conditions of flow rate 1.0 mL/min,column temperature 30 ℃ and isocratic elution.Analysis time was only 25 minutes in this method,and there was no sample pretreatment.Limit of detection ranged from 5.1 to 41.1 μg/mL,and limit of quantitative ranged from 17.0 to 137.0 μg/mL,and recovery rates ranged from 93.81% to 111.98%.Sterol linoleate and sterol oleate in the concentration range of 0.01 ~1.0 mg/mL showed a linear correlation.Linearity range of sterol linoleate and sterol oleate was 0.1 ~ 1.0 mg/mL.All the regression coefficients of standard curves were over 0.998.This method could be used in simultaneous detection of different sterol and sterol ester products,and worthy of promotion.
What problem does this paper attempt to address?