A Rapid Method for the Determination of Virginiamycin in Feeds Using Liquid Chromatography-tandem Mass Spectrometry

Wen-qing CAO,Zhen-xing WU,Ping JING,Gui-peng YANG,Li-ming LIN
DOI: https://doi.org/10.3969/j.issn.1005-6521.2015.12.021
2015-01-01
Abstract:A high performance liquid chromatography-tandem mass spectrometric (HPLC-MS/MS)method was developed for the determination of virginiamycin (VGM) M1 and S1 residues in feeds. The samples were extracted with acetonitrile, purified by freezing de-fatted and salting-out effect of saturated sodium chloride solution and redissolved in methanol-ammonium formate solution. The extracts were separated with XDB-C8 LC column using a binary eluent under gradient elution and determined by tandem mass spectrometry under positive electrospray ionization mode with multiple reaction monitoring (MRM) mode. m/z M1:526.3/355.1 and 526.3/337.2,S1:824.5/290.1 and 824.5/205.1 were selected as precursor-product ion pairs, in which 526.3/355.1 and 824.5/205.1 were used for external standard quantization. Under the optimal conditions , the calibration curve was linear over the concentration of VGM in the range of 1.0 μg/kg-1 000.0 μg/kg with correlation coefficient between 0.998 7-0.999 5. The quantitation limit of 2.0μg/kg and the detection limit was 1.0μg/kg. The average fortified recoveries of VGM from feeds at 3 spiked levels of 2.0 , 5.0 and 10μg/kg ranged from 81.0%to 105.0%with relative standard deviations(RSD)(n=6) less than 4.0%. The method showed good simplicity, sensitivity, stability, accuracy, time saving and low cost, and was suitable for the rapid determination of VGM in feedstuffs.