Seepage model and spacing design of horizontal trench in landfills

YE Jian,LAN Ji-wu,CHEN Yun-min,KE Han,WANG Ke-hong
DOI: https://doi.org/10.11779/CJGE201610024
2016-01-01
Abstract:The horizontal trench is a major leachate drainage facility in municipal solid waste (MSW) landfills, of which the spacing design affects drainage and water level greatly. Based on a new seepage model for horizontal trench, the analytical solution of saturation line and the relationship between design spacing of horizontal trench and warning water level can be deduced. The results ofnumerical calculation agree well with the analytical solutions. It is further revealed that how the inflow, saturatedhydraulic conductivity of MSW, size and spacing andequivalent hydraulic conductivity of thehorizontal trench influence the capacity of water level control. The results show that themaximum head of waste body and the head athorizontal trenchsignificantly increase when the hydraulicconductivity of horizontal trench drops below1×10-4cm/s; and it is in favor of the control of water level when the ratioof the inflow to the saturated hydraulic conductivityof MSW is less than5×10-2. A dimensionlessfigureof spacingdesign of horizontal trench is proposed, andis verified by a typical caseanalysis.
What problem does this paper attempt to address?