Efficiency of rural sewage treatment by a household multiple-cell constructed wetland system

Xinxi Fu,Xiaofu Wu,Chengye Xi,Jiaming Wang,Shushu Zhong
DOI: https://doi.org/10.3969/j.issn.1002-8471.2017.07.007
2017-01-01
Abstract:By taking into consideration the difficulty in establishment of centralized conventional sewage treatment plant in rural areas,a small-scale,assembled multiple-cell household wetland model was designed for treatment of rural sewage in southern China.The constructed model consisted of a surface-flow wetland cell connected in series with three vertical subsurface-flow wetland cells.The experimental data obtained from over a year operation period showed that the constructed model was effective to remove the tested pollutants.The annual average removal rates of TSS,COD,BOD5,TN,NH3-N and TP reached 85.3%,82.4%,80.1%,47.5%,51.1% and 61.5%,respectively.The effluent concentrations of TSS,COD,BOD5 and TN met the first grade B of the Discharge standard of pollutants for municipal wastewater treatment plant (GB 18918-2002) throughout the operation period.The removals of NH3-N and TP were less satisfactory in winter period.Decrease in temperature caused significant decrease in removal rates of nitrogen and phosphorus.In order to maintain the system treatment efficiency and stability,it is necessary to improve the operation management in cold season.