Development of a Synchronous Assay Method for Trihalomethane and Haloacetic Acid in Drinking Water Based on EPA Standards

Rui Huang,Zhiquan Liu,Boyin Yan,Yongpeng Xu,Dongmei Liu,Fuyi Cui,Peng Wang
DOI: https://doi.org/10.3969/j.issn.1002-8471.2016.05.008
2016-01-01
Abstract:In order to simplify the pretreatment method for the assay of trihalomethanes (THMs)and haloacetic acids (HAAs)in drinking water,a new method to analyze THMs and HAAs synchronously was developed.This new method takes the liquid-liquid extraction step in HAAs test as the pretreatment of THMs test,so it could improve the working efficiency by reduc-ing the pretreatment time of each sample for about one hour in simultaneous test of two matters. Comparing the accuracy,precision and the detection limit of this method with these of national standard method,it showed that when the concentration of THMs were 1~200 μg/L,the modified method has a good linear relationship between concentrations of THMs and peak area (R 2 >0.999) and its recovery rate was from 96.68% to 103.39%.For HAAs,due to the pretreatment proce-dures of the two methods were identical,the detecting result from this method was as the same as that from the national standard method.
What problem does this paper attempt to address?