The Impact of Solar Radiation on Inter-flat Contaminants Transmission Characteristics in High-rise Building

Di MU,Naiping GAO
DOI: https://doi.org/10.13614/j.cnki.11-1962/tu.2018.02.09
2018-01-01
Building Science
Abstract:In this paper,a hypothetical twenty-story high-rise building with single-sided natural ventilation was set as research object.April 21th was chosen as the represent day of transition season.Firstly,we calculated the solar intensity received by building's outer vertical wall surface in the sunny day.Then based on the heat balance equation of building wall surface,the temperature of the wall and the temperature difference between the outer wall and the ambient air could be figured out.Finally,the tracer gas method was employed in the numerical simulation to analyze the influence of the wall plume flow on the vertical inter-flat pollutant transmission characteristics.The results showed that,the temperature difference between southern and northern wall was about 10 ℃ at noon.The source was set as a point with steady intensity.When the buoyancy was stronger than the wind or approximately equivalent,the concentration of at least two flats immediately higher than the source could be in the magnitude range of 10-4 ~ 1.