Test and Analysis on the Architectural Physical Environment of Ancient Dwellings in Chengcun Village

Yi CHEN,Haolei TANG,Xiaojuan CHEN,Yufeng ZHANG
DOI: https://doi.org/10.13614/j.cnki.11-1962/tu.2016.06.02
2016-01-01
Abstract:Aimed at ancient dwellings in Chengcun village in Wuyishan city of Fujian province,the indoor and outdoor building physical environment tests were carried out respectively in winter and summer. The tests included village outdoor meteorological parameters,outdoor wind environment,indoor thermal environment and indoor light environment. The test results are as follows. The wind speed of main streets of Chengcun village was appropriate and the outdoor thermal environment was favorable all year round. In winter,the thermal environment was comfortable in bedroom throughout the day,and was comfortable in hall in daylight,but rather cold at night. In summer,it was comfortable in hall and bedroom at night,but was hot in daylight. The indoor air humidity was high all year round,this was not conducive to the thermal comfort of human body. The indoor average wind speed was very low,there was almost no wind pressure and thermal pressure ventilation. The daylight was relatively abundant in hall,but was seriously insufficient in bedroom. Compared with the ancient dwellings,air temperature in hall of the new house was higher in the night,while air temperature in bedroom of the new house was significantly higher throughout the day,and the air humidity was relatively low. The development plans for Chengcun village were also provided based on the test results.
What problem does this paper attempt to address?