Effects of Insulation Position and Thickness of Composite Wall on Building Energy Consumption
Ji-yuan ZHANG,Lian-ying ZHANG
DOI: https://doi.org/10.3969/j.issn.1673-7237.2014.08.014
2014-01-01
Abstract:Heating load and cooling load of commercial building with six kinds of composite walls in five cities of our country are calculated by software named DeST-c which is developed by Tsinghua Uni-versity. These six kinds of composite walls are respectively characterized by placing insulation at the inner surface of wall, placing insulation at the outer surface of wall, placing insulation in the middle of wall, placing half insulation at the inner surface and the other half insulation at the outer surface of wall, placing half insulation in the middle and the other half insulation at the inner surface of wall, placing half insula-tion in the middle and the other half insulation at the outer surface of wall. These five cities include Harbin, Xi’an, Shanghai, Kunming and Guangzhou. Besides, economic insulation thicknesses of this build-ing in five cities are calculated by life cycle cost analysis method. According to the results, the technology of wall insulation in different areas is analyzed.