Comparison of Stormwater Sewer Running State between LID and Traditional Development Mode

Ping XU,Heng-yang REN,Hui-wei XU,Jun-chao HE,Ya-jun ZHANG,Xin-xin REN
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2018.15.025
2018-01-01
Abstract:SWMM was used to simulate the rainwater sewer operation of low impact development (LID) mode and traditional development mode under different return periods in Menhu District of Shenzhen Guangming New District. The impact of LID technology on the running status of the stormwater sewer was analyzed from water depth of the sewer, node overflows, runoff volume, peak flow and runoff coefficient respectively. The results showed that, compared with the traditional development mode, the maximum depth of each node and peak flow under LID mode were reduced by 0.20-0.95 m and 62.7% - 67.5% respectively. In addition, peak latency was up to 11 min after using LID technology. No overflow occurred at the pipe network nodes under 1-10 years return periods. Moreover, the reduction rate of outlet runoff volume was 39.3%-50.5%, and the runoff coefficient was controlled within 0.5.