Research on heat release rate of flexible polyurethane foam

Hong-shuang WANG,Ling-ling WEI,Bing-song WANG,Chang-hai LI,Shou-xiang LU
2017-01-01
Fire Science and Technology
Abstract:Cone calorimeter was used to test the flexible polyure?thane foam, and to study the influences of external heat flux and sample thickness on foam combustion. The radiant heat flux is 15~50 kW/m2 and the density of flexible polyurethane foam is 30 kg/m3. The samples were made for 100 mm × 100 mm according to the ISO 5660. The results showed that there are two peaks in HRR curves under low heat radiation, corresponding respectively to two steps during the combustion. The first step corresponds to the melt?ing of the foam intotar, the second step corresponds to the combus?tion of the tar previously produced. There is only one step during foam combustion under high heat radiation, corresponding mainly to the combustion of the tar. And, it occurs randomly one or two steps under heat fluxes of moderate intensity, and the combustion by two steps was fully than that's of one step. There are one step and two steps during the combustion, corresponding respectively to thin and thick specimens.
What problem does this paper attempt to address?