Study on numerical simulation of fire-induced smoke movement under different smoke control methods in train compartment
Minggao YU,Jing CHEN,Guanfeng SU
DOI: https://doi.org/10.11731/j.issn.1673-193x.2017.02.021
2017-01-01
Abstract:To reveal the migration characteristic of fire-induced smoke under different smoke control methods in train compartment and select the optimal smoke control method, the simulated calculation was carried out on one compartment of the high-speed train CRH2A by using FDS (Fire Dynamic Simulation).The smoke in the compartment was controlled by mechanical smoke exhaust system, air curtain system and the coupled system of them respectively, and the change laws of smoke temperature, smoke layer height and smoke concentration in the compartment under different smoke control system were compared and analyzed.The results showed that the effect of smoke control is better with the increase of mechanical smoke exhaust rate, but the mechanical smoke exhaust rate should not be too large, when the fixed fire power is 0.2 MW, the smoke exhaust effect is the best when the mechanical smoke exhaust rate(V2) is 0.87 m3/s.The air curtain can impede the spreading of smoke to adjacent compartment to some extent, and the effect of mechanical smoke exhaust on reducing smoke temperature and concentration is more obvious than that of air curtain system, but the effect of each independent system is far less than that of the coupled system.Comprehensively considering the effectiveness and economics of smoke control, the optimal combination mode of smoke control was the air curtain rate (V1) is 1.12 m3/s and the mechanical exhaust rate (V2) is 1.62 m3/s under the conditions of this paper.
What problem does this paper attempt to address?