Internal circulation autothermal thermophilic aerobic digestion for sewage sludge treatment

Wenhao LI,Ningben JIN,Ziyang LOU,Nanwen ZHU,Haiping YUAN
DOI: https://doi.org/10.12030/j.cjee.201610048
2017-01-01
Abstract:In order to improve the efficiency of sludge digestion, an internal circulation autothermal thermophilic aerobic digestion with an inner cylinder was investigated.The sludge was cycled between inner and outer cylinder.The results showed that in internal circulation autothermal thermophilic aerobic digestion(ATAD) system,the removal of volatile solids (VS) at 16 d was 41.52%.At 20 d, the removal of VS was increased 11.39%than no internal circulation.With the inner cylinder, the value of ORP and pH both in the top and bottom maintained in a higher level, the anaerobic condition was relieved.The pH, ORP, NH4+-H, SCOD, TVFA, TN and TP concentrations in the top of reactor were in accordance with those in the bottom.The sludge could be mixed more homogeneous with the inner cylinder.