Study on Micro-polluted Water Treatment by Ozone/Ceramic Membrane and Membrane Fouling

Bowen LI,Xiang LI,Li ZHOU,Yaoyao JI,Huiping DENG
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2018.01.025
2018-01-01
Abstract:Anintegrated process of pre-ozonationand ceramic U Fmembrane filtration was applied to treatmicro-pollutedwater.The influence ofthree ceramic membranes with different molecular weight cut-offs (MWCO) on the hybrid process were investigated.Research results showed that,compared with membrane filtration alone,the membrane flux of 15 k,50 k,150 k ceramic membrane was improved by 1.2%~2.6%,6.0%~10.5% and 4.2%~8.4%,respectively after ozone pretreatment.Ozone had the biggest influence on 50 k aceramic membrane,and the best optimization dosage of ozone was 2 mg/L.When ozone dosage was 2 mg/L,the removal rate of CODMnby 15 k,50 k and 150 k was 29.2%,24.7% and 19.5% respectively,and removal rate of UV254 was 40.0%,36.7% and 41.3%,respectively.Through the analysis of three-dimensional fluorescence,Fulvic acid-like components was the main pollutant of membrane fouling,and thecontribution order of organic matter with different component for irreversible fouling potential was HPI>HPO>TPI.