Renovated method for liquid level monitoring of the processing instruments based on the PSO-SVM principle

Xiao-xia CHEN,Xue-feng HAN,Yao DENG,Jun-cheng JIANG,Jing-hua TANG
DOI: https://doi.org/10.13637/j.issn.1009-6094.2017.01.021
2017-01-01
Abstract:This paper is aimed at introducing a renovated method for liquid level monitoring of the processing instruments based on the PSO-SVM principle in order to solve the problem on how to apply the idea of soft measurement to the monitoring of the industrial production.The said renovated method is intended to be used directly for measuring the production process to ensure the production safety by avoiding the false level interference in it.However,there still exist some assumptions made by using the method,saying that it cannot fully reflect the reality of the actual industrial production system.Therefore,as a means of supplementation,we have proposed a so-called PSO-SVM method for the liquid level monitoring of the processing instruments based on the data-driven modeling under the support of the vector machine sparse for the small samples with the nonlinear high dimensional data.In so doing,it would be possible to overcome the known "dimension disaster" by avoiding being trapped into the local minimum dots.However,on the whole,the method we have developed proves to perform successfully in generalization ability and stand out in the data-driven modeling methods.In order to optimize the functions of the model,we have managed to use the particle-swarming optimal algorithm to optimize the parameters based on the SVM model.Last of all,we have also established a mathematical model based on the PSO-SVM for analyzing the liquid level monitoring of the SBR discharge chute by taking into account the three auxiliary variables,that is,the feed pressure of manifold PI,the inlet temperature of the discharge chute TA and the pressure of the butadiene separation system Po so as to get the level of the discharge chute L.The reliability and validity of the application results of the model show that the predicted values prove to be well in accord with the actual ones,wheres the model turns to be successful in operation as is predicted.Thus,the model we have established can be taken as a reference to the effective monitoring of the liquid level of SBR discharge chute due to its nice performance in the actual application so as to avoid "the false level" interference and ensure the production safety.
What problem does this paper attempt to address?