Effect of temperature and COD on ability of denitrifying phosphorus removal in SBR

Fang-ying JI,Qian GAO,Chun-hua YUAN
DOI: https://doi.org/10.3969/j.issn.1009-6094.2005.06.009
2005-01-01
Abstract:The present paper aims to examine the effect of temperature and COD on the ability of denitrifying phosphorus removal in SBR.The results show that good performance of denitrifying phosphorus removal can be obtained between 18 ℃ and 37 ℃,and the change of temperatures may not affect △NO~-_3N/△PO~(3-)_4P.At the same time,it is found that the consumption of carbon in SDPR(simultaneous denitrifying phosphate removal) system can be less than that of the traditional phosphorus removal system(anaerobic/aerobic) by 33% when the phosphorus is less than 0.5 mg/L(PO~(3-)_4P) in effluent.Whereas the PO~(3-)_4P in influent can be as high as 8.0-9.2 mg /L,COD is only 220-240 mg/L,PO~(3-)_4P in effluent of SDPR system,which is less than 0.5 mg/L.However,in order to get the same PO~(3-)_4P removal in traditional phosphorus removal system(anaerobic/aerobic),about 350 mg/L HAC-COD in influent proves to be absolutely necessary.
What problem does this paper attempt to address?