Studies on the treatment of antibiotics pharmacy-based mixed industrial wastewater using composite technology

Jianfa Chen,Cheng Lin,Fuquan Liu
2014-01-01
Abstract:Acco rding to the refractory feature of antibiotic industrial wastewater , the combined process , anaerobic hydrolysis+MSBR+ozonation+flocculation+BAF has been used in a wastewater treatment plant in the industrial centralized district for treating the mixed industrial wastewater ,which is antibiotic pharmacy-based mixed industrial wastewater . The results show that when the average concentration of COD , NH3-N and TP in the influent are 485,41.2 and 7.66 mg/L respectively,and the average concentration in the effluent is 81,9.3 and 0.331 mg/L, respectively,reaching all the indexes stipulated in the first grade of Integrated Wastewater Discharge Standard (GB 8978—1996). The successful application of this composite process provides a new method for treating mixed industrial wastewater which has been impossibly hard to be degraded.