Emission Factors of CO and NOx of Urban Tunnel with Concave Structure Based on Measurement Method

Chao CHEN,Qin-qiang HU,Yi-wen DEGN,Qiong LI,Yan LI
DOI: https://doi.org/10.3969/j.issn.1001-7372.2017.09.015
2017-01-01
Abstract:To characterize the emission of vehicles in urban tunnels,the field measurement was conducted on CO and NOx concentration together with relevant parameters in cross-river tunnel of East Yan'an Road,cross-river tunnel of Xiangyin Road in Shanghai and Xiang River Tunnel of Yingpan Road in Changsha from 2012 to 2013,based on measurement method of the tunnel.The data reflecting in-use fleet average emission factors of CO and NOx in urban tunnels of China were deduced.The results show that as for one-way twin-bore tunnels with concave structure,the effect of natural ventilation caused by external factors is limited.The ventilation caused by movement of vehicles has a positive effect on pollutant dispersion and dilution.In-use fleet average emission factors of CO and NOx are (0.754±0.561)-(6.050±5.940),and (0.121± 0.022)-(0.818±0.755) g· km-1 · vehicle-1 respectively when gradient is from-6% to 6%.The findings in accordance with results calculated by Permanent International Association of Road Congresses (PIARC) in 2012 are significantly less than designed values in the current specifications of highway tunnels.The results can provide references for the engineering design of ventilation in urban tunnel of China.
What problem does this paper attempt to address?