Effect of quadratic damping in a shock isolation system

Chun-hui ZHANG,Jian-hua ZHAO,Yu WANG,Yong CHEN
DOI: https://doi.org/10.3969/j.issn.1007-7294.2014.07.013
2014-01-01
Abstract:It is considered that damping has not significant effect on structure’s maximum response when the structure is suffered from a short time shock in the conventional shock isolation design. Therefore, a tradi-tional shock isolation system is often designed on the selection of appropriate stiffness and ignoring the damp-ing effect, which could not restrain both the absolute acceleration maximum and the relative displacement amplitude at the same time. This shock isolation system could not meet the shock isolation requirements of ships. A single-degree-of freedom quadratic damping shock isolation system model is built here. Effect of quadratic damping in a shock isolation system is studied by numerical simulations. It is indicated that us-ing quadratic damping can obviously improve its shock isolation performance and reduce the relative dis-placement amplitude. Quadratic damping shock isolation system can obtain smaller response amplitude than linear damping system under the identical shock conditions. Velocity step equivalent method is not suit-able for the calculation of absolute acceleration shock isolation system, but it can calculate the relative dis-placement.
What problem does this paper attempt to address?