Percutaneous pericardial puncture for mapping and ablation of ventricular arrhythmias: safety and efficacy

Chunyu ZHANG,Zhenning NIE,Shimo DAI,Baozhen QI,Jinyi LIN,Jiaxiong LIN,Junbo GE
2017-01-01
Abstract:Objective To evaluate the safety and efficacy of percutaneous subxiphoid pericardial puncture for mapping and ablation of ventricular arrhythmias.Methods Clinical data of 10 patients with ventricular arrhythmias who underwent pericardial puncture for epicardial mapping and ablation from June 2014 to December 2015 were retrospectively analyzed in this study.There were 8 males and 2 females aged from 16 to 69 years.One suffered from idiopathic ventricular arrhythmias and nine had structural heart disease combined with ventricular tachycardia (8 with non-ischemic cardiomyopathy and 1 with ischemic cardiomyopathy).Six patients with structural heart disease received cardic-resynchronization therapy with a defibrillator (CRT-D) or implantable cardioerter defibrillator (ICD) before the procedure.Four patients had a history of failed endocardial ablation.The complications of pericardial puncture were evaluated.The efficacy of pericardial mapping and ablation was analyzed.Results The pericardial punctures were done successfully in all the patients.Pericardial bleeding occurred in one patient,which might be caused by right ventricular injury and was cured by drainage.No pericardial tamponade,coronary vessel damage,injury to subdiaphragmatic vessels and abdominal viscera or phrenic nerve injury occurred.Acute endocardial ablation was achieved (45 W,90 s,2 times) in the patient with idiopathic ventricular arrhythmia after endo-epicardial mapping.For the patients with structural heart disease,ablation targeted the local abnormal ventricular activities (LAVAs).Of them,acute epicardial ablation was achieved successfully in 7 patients after endo-epicardial mapping,but it failed in 2 patients because of intramural ventricular arrhythmia.Ablation catheter was tried to reach the branches of the coronary sinus in the 2 failed patients;however,it still failed.In the 4 patients with previous failed endocardial ablations,after endo-epicardial mapping,epicardial ablation was achieved successfully in 3 patients and endocardial ablation finished in 1 patient.During follow-up (3-12 months),2 cases recurred.One of them died from refractory heart failure.Conclusion Percutaneous subxiphoid pericardial puncture and ablation is safe and effective in patients with ventricular arrhythmia.Endo-epicardial mapping can improve the efficiency of ablation in patients with structural heart diseases (Shanghai Med J,2017,40:201-205)
What problem does this paper attempt to address?