Investigation and Control for Fecal Coliform Pollution Source in Chongqing Municipal Wastewater

Dong LI,Sheng ZHANG,Chuan HUANG,Ming HE
DOI: https://doi.org/10.3321/j.issn:1000-4602.2005.08.006
2005-01-01
Abstract:Sampling survey was conducted on the outfall of urban wastewater and hospital wastewater in districts of Chongqing City. The result shows that the fecal coliform (FC) value in the untreated urban wastewater is about 10~6-10~7 cfu/L with the difference between maxmum and minimum value as large as 4 lg. The disinfection device was set up in the hospital wastewater treatment system, but due to improper management, the fecal coliform in effluent was seriously out of standard with the value of 10~4-10~5 cfu/L, which was lower than that in urban wastewater. Comparison was made on the effluent fecal coliform values from the wastewater treatment plant with and without disinfection device. By making techno-economic comparison, chlorine, UV and ozone disinfection serve their different functions in disinfection of urban wastewater, reused water, and hospital wastewater, and they shall be adopted individually or in combination according to the specific condition.
What problem does this paper attempt to address?