Performance study on the centralized solar hot water system

Hongbing Chen,Qiang Li,Xilin Chen,Lei Zhang,Sai Chu,Danming Luan
DOI: https://doi.org/10.3969/j.issn.1671-5292.2017.04.022
2017-01-01
Abstract:Solar fraction is important index to evaluate the energy saving effect of solar hot water system.In fact,it has the certain limitation and fails to achieve the energy saving effect if you evaluate the solar hot water system by it only.So,the article takes a certain residential centralized solar hot water system of Tianjin as the object of study and we establish the mathematical model and carry out the simulated calculation to its performance.Based on the simulated results,we conduct a series of study,which include system performance throughout the year,water consumption and control strategies have the effects on system performance and put forward taking solar fraction,solar energy utilization efficiency,conventional energy efficient replacement rate,system heat dissipation rate four parameters as system performance evaluation index as well as the control strategy of reducing the water cycling time properly.
What problem does this paper attempt to address?