Effect of Post-Rinsing Time on the Mechanical Strength and Cytotoxicity of a 3D Printed Orthodontic Splint Material

Yichen Xu,Alexander B. Xepapadeas,Bernd Koos,Juergen Geis-Gerstorfer,Ping Li,Sebastian Spintzyk
DOI: https://doi.org/10.1016/j.dental.2021.01.016
IF: 5.687
2021-01-01
Dental Materials
Abstract:Objective. Since the post-rinsing time is inconsistently recommended, this study aims to investigate the effect of post-rinsing time on the flexural strength and cytotoxicity of an stereolithographically (SLA) printed orthodontic splint material. Methods. SLA-printed specimens were ultrasonically rinsed with isopropanol (IPA) for 5 min, 12 min, 20 min, 30 min, 1 h, and 12 h, respectively. Surface characterization was conducted by scanning electron microscopy and roughness measurements. Flexural strength was evaluated using a three-point bending test. Cytotoxicity was determined by direct contact test and extract test. For both tests, cell viability (live/dead staining) and cell metabolic activity (CCK-8 assay) were evaluated. Additionally, water sorption and water solubility were tested to analyze the mass loss from immersion. Results. No apparent surface alterations could be detected on the samples post-rinsed for less than 1 h. In contrast, when the post-rinsing time was prolonged to 12 h, surface fissures could be observed. Flexural strength linearly decreased with increasing post-rinsing time. All post-processed specimens did not show an obvious cytotoxic effect. Significance. The removal of cytotoxic methacrylate monomers by post-rinsing with IPA could be achieved in 5 min. Extending post-rinsing time could not improve the cytocompatibility of the SLA-printed orthodontic splint material, and may result in a decrease in flexural strength. (c) 2021 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
What problem does this paper attempt to address?