Effective glyphosate degradation through the combination of ozone/hydrogen peroxide oxidation and coagulation

Lei Chen,Shengbao Zhou,Yanhua Xu,Yongjun Sun,Huaili Zheng
DOI: https://doi.org/10.5004/dwt.2020.26261
IF: 1.1
2020-01-01
Desalination and Water Treatment
Abstract:Phosphorus removal from glyphosate wastewater is a common problem that requires an urgent solution. In this study, ozone-catalyzed oxidation coupled with coagulation is used to treat glyphosate-simulated wastewater. The effect of ozone dosage, hydrogen peroxide, pH, reaction time, and amount of catalyst on the efficiency of glyphosate removal, color, biological toxicity, total phosphorus, organic phosphorus, and inorganic phosphorus are studied in ozone-catalyzed oxidation. Afterward, the effect of coagulant species, pH, dosage, stirring rate, stirring time, and water temperature on the efficiency of glyphosate removal, total phosphorus, organic phosphorus, and inorganic phosphorus by coagulation process are also investigated. The removal rates of glyphosate and chroma reach 56.97% and 93.75%, respectively, at the optimal conditions of ozone-catalyzed oxidation, and the biological toxicity of wastewater changes from high to low. Ozone-catalyzed oxidation can effectively reduce color and wastewater biological toxicity. After the ozone-catalyzed coupled coagulation treatment, the removal rates of glyphosate, total phosphorus, organic phosphorus, and inorganic phosphorus by the coagulation process reach 71.13%, 93.75%, 90.48%, and 96.3%, respectively, at optimal conditions. This study demonstrates the effectiveness and superiority of ozone-catalyzed oxidation and coagulation coupling for glyphosate degradation.
What problem does this paper attempt to address?