Frost Resistance of Concrete for Arch Dam of Jinping Hydropower Station I

唐天国,段绍辉,段云岭
DOI: https://doi.org/10.3969/j.issn.1000-0860.2010.12.006
2010-01-01
Abstract:Based on the in-situ placement of concrete for the construction of Jinping Hydropower Station I,the tests of freeze-thawing cycle are made on the samples taken from the typical locations of the dam body along with the measurements made on their relative dynamic elastic modulus and mass loss coefficient.During the freeze-thawing process,50 cycles are taken as the freeze-thawing cardinal number;after which the measurements on the relative dynamic elastic modulus and mass loss coefficient are made immediately with the observation on the general frost resistance of the sample.The result shows that the testing effects of both the samples taken from the exit of the concrete mixer plant and the site of the placement are more obvious,however,the relevant frost resistances can generally meet the those requirements specified in the design concerned.