Determination and Analysis of Environmental Quality of Enclosed Layer House with Eight Overlap Tiers Cages in Winter
Jun-ying LI,Xuan-jiang YANG,Kai ZHAN,Hua-long LI,Sheng-nan LIU,Wei LIU,Yan LI,Rui-yu MA,Shuang WANG
DOI: https://doi.org/10.16213/j.cnki.scjas.2017.6.039
2017-01-01
Abstract:[Objective] The environment quality parameters of enclosed layer house with eight overlap tiers cages in winter was measured and analyzed in order to provide preference for environment quality of layer production.[Method] The environment quality parameters (temperature,relative humidity,light intensity,CO2 concentration,air velocity,dust concentration,NH3 concentration and PM10) were measured by the intelligent monitoring system and dust sampler horizontally and vertically in an enclosed layer house with six overlap tiers cages,respectively.These data were collected during the period of 6:00 to 8:00,12:00 to 14:00 and 18:00 to 20:00 every day in winter,respectively.[Result] The average values of temperature,relative humidity,air velocity,light intensity,carbon dioxide concentration,dust concentration,NH3 concentration,and PM1o in enclosed layer house with eight overlap tiers equipped with side window ventilation system in winter were 19.11 ℃,52.02 %,0.25 m/s,34.00 lx,2083.22 mg/m3,2.85 mg/m3,1.04 mg/m3 and 26.01 μg/m3,respectively.The environmental quality parameters of different measuring points were different in the experimental layer house.The temperature,the concentration of CO2,dust concentration,NH3 concentration,and PM10 became greater along with the distance from the damp curtain to fan side,respectively.The temperatures,carbon dioxide concentration,and NH3 concentration of upper measuring points of H3.80 m,H4.50 m and H5.10 m were significantly higher than that of the1ower measuring points of H0.60m,H1.30m and H1.90m,respectively.Correlation analysis indicated that,there was extremely significantly positive correlation between temperature and carbon dioxide concentration and oxygen content.The air velocity and temperature,CO2 concentration,NH3 concentration,dust concentration was significantly negative correlated.The temperature showed extremely significantly positive correlation with NH3 concentration.[Conclusion] The environment quality parameters were different at horizontal and vertical measuring points in the enclosed layer house with eight overlap tiers cages in winter,and could meet the demands of standard of Environmental quality standard for the livestock and poultry farm (NY/T388-1999).