A 3-Cell Deflecting Rf Cavity for Emittance Exchange Experiment at ANL.
Jiaru Shi,Huaibi Chen,Chuanxiang Tang,Shuxin Zheng,Wenhui Huang,John G. Power,Chunguang Jing,Kwang-Je Kim,Wei Gai,Derun Li
DOI: https://doi.org/10.1016/j.nima.2008.09.046
IF: 1.335
2008-01-01
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Abstract:An RF deflecting structure has been designed and fabricated for a transverse-to-longitudinal emittance exchange experiment at Argonne National Laboratory (ANL) [Y.-E. Sun, et al., Design study of a transverse-to-longitudinal emittance exchange proof-of-principle experiment, in: Proceedings of PAC-2007, Albuquerque, NM, USA, 2007, pp. 3441–3443 [1]]. The structure is a 1300MHz normal conducting RF cavity consisting of three cells operating in a dipole (TM110-like) mode. As high as 3.4MV deflecting voltage is required for the experiment. In this paper, we present detailed RF design of the cavity, particle tracking simulations in the cavity and low power RF measurement results in comparison with numerical simulations. The cavity cell geometries (gaps in particular) are optimized to giving a zero orbit offset for particles crossing the cavity with zero-phase.