Abstract:Ratiometric fluorescent films with high amine sensitivity and stability were developed to monitor the freshness of beef and pork. Fluorescein isothiocyanate (FITC) and red carbon quantum dots (R-CQD) were used as the amine-responsive indicator and internal reference, respectively. The electrospun films prepared by immobilizing FITC and R-CQD complex (F-R) into polyvinylidene fluoride (PVDF) under 35 %, 55 % and 75 % of relative humidity (RH) were named F-R@PVDF-1, F-R@PVDF-2 and F-R@PVDF-3, respectively. In comparison, the F-R@PVDF-2 film exhibited the highest sensitivity to trimethylamine (TMA), demonstrating a limit of detection (LOD) value of 1.59 μM, and meanwhile high stability during storage with ΔE value of 1.99 after 14 days of storage at 4 °C. The F-R@PVDF-2 film also showed a significant fluorescent red-to-brown color change during meat freshness monitoring at 4 °C. Conclusively, this study reported a new ratiometric fluorescent film that can be used to track the freshness of meats in food packaging.