A Voltammetric Sensor Based on Reduced Graphene Oxide-Hemin-ag Nanocomposites for Sensitive Determination of Tyrosine.

Hui-Yu Zou,Xin-Yang Lu,Fen-Ying Kong,Zhong-Xia Wang,Heng-Ye Li,Hai-Lin Fang,Wei Wang
DOI: https://doi.org/10.1039/d0ra04976j
IF: 4.036
2020-01-01
RSC Advances
Abstract:A novel voltammetric sensor was designed and used for the determination of l-tyrosine (l-Tyr) by surface modification of a glassy carbon electrode with reduced graphene oxide-hemin-Ag (rGO-H-Ag) nanocomposites. The nanocomposites were synthesized by a facile one-pot hydrothermal method and characterized by means of transmission electron microscopy and Raman spectroscopy. The determination of l-Tyr was investigated by cyclic voltammetry and further quantified using differential pulse voltammetry. The results revealed a significant enhanced electrochemical oxidation effect for l-Tyr at the nanocomposites modified electrode. Two linear ranges from 0.1 to 100 μM and 100 to 1000 μM as well as a low detection limit of 30 nM (S/N = 3) were obtained. In addition, the sensor also demonstrated good selectivity, reproducibility and stability.
What problem does this paper attempt to address?