AirNet: Fused Analytical and Iterative Image Reconstruction Method with Deep Learning Regularization for High-Quality Sparse-Data On-Board CBCT

G. Chen,Y. Lin,E. Elder,B. Ghavidel,M. W. McDonald,K. M. Langen,J. D. Bradley,T. Liu,H. Gao
DOI: https://doi.org/10.1016/j.ijrobp.2020.07.729
2020-01-01
Abstract:On-board cone-beam CT (CBCT) is commonly used during radiation therapy for patient positioning and other purposes. In particular, 4D CBCT is desirable for motion-resolved imaging of moving tumors e.g., for lung, pancreatic and liver cancer patients; limited-angle or sparse-view CBCT can monitor treatment delivery, e.g., via triggered imaging. Mathematically these can be categorized as sparse-data image reconstruction problem that is still unsolved. This work will develop a new reconstruction method titled AirNet for high-quality sparse-data CBCT image reconstruction. AirNet is designed to incorporate the benefits from analytical reconstruction method (AR), iterative reconstruction method (IR), and deep neural networks (DNN). AirNet built upon fused analytical and iterative reconstruction (AIR) that synergizes AR and IR via the optimization framework of modified proximal forward-backward splitting (PFBS). By unrolling PFBS into IR updates of CT data fidelity and DNN regularization with residual learning, AirNet utilizes AR such as FBP during the data fidelity, introduces dense connectivity into DNN regularization, and learns PFBS coefficients and DNN parameters that minimize the loss function during the training stage. With trained parameters AirNet can then be used for end-to-end image reconstruction. Additionally, two different strategies are developed for 4D-AirNet: prior-guided (PG) and all-phase (AP). PG-AirNet utilizes phase-by-phase training and reconstruction, while PG-AirNet uses a prior image reconstructed with all ten-phase projection data. CT libraries of prostate and lung scans was used to validate the AirNet in comparison with state-of-art DNN-based post-processing and image reconstruction methods. The validation loss in AirNet had the fastest decreasing rate, owing to inherited fast convergence from AIR. AirNet was robust to noise in projection data and content differences between the training set and the images to be reconstructed. In addition, AP-AirNet provided the best reconstruction quality overall for 4D CBCT. A new image reconstruction AirNet is developed for high-quality sparse-data CBCT image reconstruction. AirNet achieved the best image reconstruction quality among all methods under comparison for all sparse-data scenarios (sparse-view, limited-angle, and 4D CBCT).
What problem does this paper attempt to address?