Planning CT-based Radiomics for the Prediction of Tumor Response to IMRT in Locally Advanced Cervical Cancer

K. Ren,L. Shi,J. Di,L. Shen,K. Hu,X. Hou,F. Zhang
DOI: https://doi.org/10.1016/j.ijrobp.2020.07.1532
2020-01-01
Abstract:This study aimed to investigate whether pretreatment planning CT-based radiomics can predict the tumor response to intensity-modulated radiation therapy (IMRT) for locally advanced cervical cancer (LACC). We retrospectively collected the planning CT images of 257 LACC patients who received definitive IMRT at one institution. The tumor response was evaluated using Response evaluation criteria in solid tumors (RECIST) 3 months after completion of treatments. Patients were scanned using a CT scanner, with the imaging parameters were 100-140kVp, 54-519mA and 500-1000ms. The pixel sizes of the CT images were 0.7mm to 1mm; the slice thicknesses were 3mm to 5mm. All images were resampled to 1mm x 1mm x 3mm and rescaled to an 8-bit depth before feature extraction. The radiomics features was extracted within the contoured gross tumor volume (GTV) and lymph nodes using an open source software, IBEX. A total of 1134 radiomics features were extracted for each patient, including the first-order features that were derived directly from the intensity histogram and high-order features that were calculated based on gray-level co-occurrence matrix (GLCM), gray-level run length matrix (GLRLM) and neighborhood intensity difference matrix (NIDM). The patients were classified into two groups: complete response (CR) group and non-CR group according to the RECIST. We used the two-sided Wilcoxon rank-sum test to calculate the differences of the radiomics features between two groups, and the features with P<0.05 were selected for further feature selection and the prediction of tumor response using a sequential backward elimination support vector machine (SBE-SVM) algorithm. The patients were divided into the training set (192) and the test set (65); the training set was used to train and optimize the model in a 10-fold cross validation. The SBE-SVM algorithm finally selected eight predictive radiomics features, including GLCM-max probability, GLRLM-short run high gray level emphasis, intensity-percentile, Compactness, volume and etc. The prediction accuracy and area under curve of the model in the test set were 78.5% and 0.84. This study demonstrates that the pretreatment planning CT based radiomics are able to predict the tumor response in LACC.
What problem does this paper attempt to address?