A nonconvex truncated regularization and box-constrained model for ct reconstruction

Weina Wang,Chunlin Wu,Yiming Gao
DOI: https://doi.org/10.3934/ipi.2020040
2020-01-01
Abstract:X-ray computed tomography has been a useful technology in cancer detection and radiation therapy. However, high radiation dose during CT scans may increase the underlying risk of healthy organs. Usually, sparse-view X-ray projection is an effective method to reduce radiation. In this paper, we propose a constrained nonconvex truncated regularization model for this low-dose CT reconstruction. It preserves sharp edges very well. Although this model is quite complicated to analyze, we establish two useful theoretical results for its minimizers. Motivated by them, an iterative support shrinking algorithm is introduced. To handle more nondifferentiable points of the regularization function except zero point, we use a general proximally linearization technique at them, which is helpful to implement our algorithm. For this algorithm, we prove the convergence of the objective function, and give a lower bound theory of the iterative sequence. Numerical experiments and comparisons demonstrate that our model with the proposed algorithm performs good for low-dose CT reconstruction.
What problem does this paper attempt to address?