Collaborative Detection for Wound Infections Using Electronic Nose and FAIMS Technology Based on a Rat Wound Model

Tong Sun,Jiao He,Shenyi Qian,Yangting Zheng,Kun Zhang,Jing Luo,Fengchun Tian
DOI: https://doi.org/10.1016/j.snb.2020.128595
IF: 9.221
2020-01-01
Sensors and Actuators B Chemical
Abstract:For years, electronic nose has been extensively studied for identifying bacteria or wound bacterial infections, which was commonly based on in vitro experiments. In this paper, based on rat in vivo experiments, we integrated two odor-sensing technologies - electronic nose and FAIMS (Field Asymmetric Ion Mobility Spectrometry)- to discriminate three common wound bacterial infections and non-infection by directly sniffing the rat wound samples. With a set of dedicated information fusion algorithm, we effectively fused the information acquired by the two technologies and obtained high rat recognition rates under real independent leave-one-out cross-validation. For the wounds 24 h/48 h after inoculation, the collaborative detection of the two technologies achieved 94.63 %/88.05 % mean accuracy, 96.67 %/98.75 % sensitivity, 90.00 %/88.89 % specificity, 94.78 %/87.62 % macro F1 score, and 94.59 %/87.28 % micro F1 score, which showed better performance than either of the two technologies. The results demonstrated the potential of odor-sensing technology as a convenient screening and monitoring method for wound infections.
What problem does this paper attempt to address?