17.4: Simple and Fast Measurement of Gamut Volume of Three Primary Display System by Colorimeter
Yuhua Yang,Binghui Yao,Guan Wang,Chun Gu,Lixin Xu
DOI: https://doi.org/10.1002/sdtp.14398
2021-01-01
Abstract:Color gamut indicates the ability to display colors for a display system. Measurement of the color gamut in three-dimensional color space is important for a display system. Compared with primary triangle in CIE xy or CIE u’v’ chromaticity diagram, the influence of brightness is considered, and the three-dimensional color space is more uniform, which is closer to the actual situation of the display system [1]. In this paper, using a colorimeter, we propose a new method to measure the gamut of three primary display system by measuring some feature points. They are located on vertexes, edges and surfaces of the three-dimensional gamut boundary. Based on these feature points, the profile of the gamut is drawn in CIExyY and CIELAB space. To calculate the color gamut of the display system, Traditional method is to calculate the area of the primary triangle in CIE xy or CIE u’v’ chromaticity diagram. CIE recommended the Segment Maxima algorithm to calculate color gamut [2]. The specific process is to sample three primaries through many images, then select outermost points of the color gamut and connect into boundaries in CIELAB color space. However, it has not been reported that the gamut volume could be measured by a colorimeter. Compared with the algorithm, our measurement method is relatively efficient. The accurate gamut of color solid is obtained in CIELAB space. In general display equipment, the intensity of each primary is divided into 256 gradients (which are not nonlinear corresponding to the lightness value). 1. Seven vertexes of color solid which are (0, 0, 255), (0, 255, 0), (255, 0, 0), (0, 255, 255), (255, 0, 255), (255, 255, 0), (255, 255, 255), meaning that one or more primaries have the maximum outputs. 2. To improve the accuracy, points also need to be taken on the edges of color solid between two vertexes for measurement. The bisection points between two vertexes are (128, 0, 0), (0, 128, 0), (0, 0, 128), (0, 255, 128), (255, 0, 128), (255, 255, 128), (0, 128, 255), (255, 128, 0), (255, 128, 255), (128, 0, 255), (128, 255, 0), (128, 255, 255). The measurement is performed in a dark room. The required colors are generated by software Microsoft paint and MATLAB. CS-2000 colorimeter of Konica Minolta is used to measure the coordinates with the perspective of 0.2°. The coordinates of each color are measured for many times and the average value is taken. We measure the color gamut of three primary laser display system and LCD computer screen in CIELAB space as an example. We compare the results with gamut volume by theoretical calculation in CIELAB space [3]. The results are shown in CIELAB space in Fig. 1.