Internal chlorination of Ni-Cr-Ce alloy exposure to chlorine at 575 degrees C

JP Tu,MS Liu,ZY Mao,ZZ Li
IF: 3.752
1996-01-01
Transactions of Nonferrous Metals Society of China
Abstract:The kinetics of internal chlorination of Ni-Cr-Ce alloy in chlorine at 575 degrees C has been studied. Internal chlorination of Ni-Cr-Ce alloy occurred to formation of CrCl2 and CeCl3 solid precipitates which is thermodynamically stable and has lower vapor pressure at the temperature along grain boundaries. At initial corrosion stage, the internal chlorination rate nearly followed parabolic rate law, the internal chlorination was accompanied by the consumption of the alloy by volatilization corrosion which obeyed a linear rate equation, the thickness of the internal chlorination region would be governed by a paralinear rate equation. After a sufficiently long period of corrosion, the rate of internal chlorination would be equal to the rate of overall metal consumption, the depth of internal chlorination approaches a steady state value. Addition of Ce to Ni-Cr alloy increased the degree of internal chlorination.
What problem does this paper attempt to address?