Flow excursion in natural circulation system

SY Jiang,YJ Zhang,XX Wu,JH Bo,ZY Liu,HJ Jia
1999-01-01
Abstract:The experiment was performed on the test loop (HRTL-5), which Simulates the geometry and system design of a 5MW nuclear heating reactor. The phenomenon of static flow excursion and the dynamic,flow oscillation occurred in the process of static flow excursion in natural circulation are described. The fluctuation behavior of mass flow rate, inlet and exit temperature of heated section during the flow excursion and the dynamic flow oscillation is studied. The experimental results show that, firstly, the variation of flow resistance caused by subcooled boiling is the main reason of static flow excursion; secondly, in the process of flow excursion the mass now rate and the inlet temperature decrease, while the exit temperature increases; thirdly, as the process of the flow excursion continues, dynamic flow oscillation with both features of density wave and geysering instability occurs in the system simultaneously with the static flow excursion. Based bn the phenomenon description, the mechanism of the static and dynamic flow instability is interpreted.