Segmented time-frequency peak filtering for random noise reduction of MRS oscillating signal

Lin TingTing,Zhang Yang,Yang Ying,Yang YuJing,Teng Fei,Wan Ling
DOI: https://doi.org/10.6038/cjg2018M0055
2018-01-01
Abstract:Magnetic resonance sounding (MRS) signal is weak, and the measurement always suffers bad signal-to-noise ratio (SNR). For the random noise interference, it is difficult to remove, because the random noise has stochastic property and always mixing with desired signal. More information is provided to signal processing and inversion interpretation by MRS oscillating signal which recorded at 10(4) - 10(5) Hz sampling rate, but as long as the average magnitude of random noise is larger than that of signal, the accuracy of parameter estimation will be reduced. The common method for random noise reduction is stacking, but it requires multiple recordings and often limited to the slow measurement progress. Considering the MRS oscillating signal has the characters of large number of samples and high nonlinearity, the general objective of this study is to employ a segmented time-frequency peak filtering (STFPF) to recover the desired signal embedded in the noisy MRS oscillating data. Firstly, the noisy signal is divided into several segments. By transforming each segment of the signal into instantaneous frequency (IF) of the analytic signal, and calculating the time-frequency distribution of the analytic signal with a small windowed pseudo Wigner-Ville transform, then significant energy concentration is produced around the IF on the time-frequency plane. Subsequently, the unbiased estimation of underlying MRS signal is achieved by taking the peak of the time-frequency distribution of analytic signal. In order to verify the effectiveness of the proposed method, an analysis has been done which compared to the traditional stacking method. Numerical simulation shows that the desired MRS oscillating signal can be recovered from a single recording in noise level down to 5 dB by applying STFPF method. The SNR is increased 23. 19 dB, the fitting error of initial amplitude is 3. 03% and the fitting error of the transverse relaxation time is 2. 7% after filtering. It performs better than the traditional stacking method. In addition, it is unnecessary to sample multi-recordings, and this will improve the measurement efficiency. Moreover, the effectiveness of STFPF method is further demonstrated by the retrieved model after inversion. The results of the proposed method in this study lay a good foundation for the real data processing.
What problem does this paper attempt to address?