Determination of 22 Triazine Herbicides Residual in Corn by Enhanced Matrix Removal QuEChERS-Ultra Flow Liquid Chromatography-Tandem Mass Spectrometry

Wu Yan,Zhao Wei,Liu Yong,Jiang Bing,Wei Dong-Xu,Gou Yue,Li,Han Feng,Zu Yuan-Gang
DOI: https://doi.org/10.11895/j.issn.0253-3820.160012
IF: 1.193
2016-01-01
Chinese Journal of Analytical Chemistry
Abstract:An enhance matrix removal (EMR) QuEChERS method for simultaneous determination of 22 triazine herbicide residuals such as atrazine, propazine, terbumeton, and desmetryn in corn was established and validated. The corn samples were initially extracted with acetonitrile (MeCN) in high. speed homogenization, and the targeted pesticides were prepared using EMR. Lipid (Enhanced matrix removal. lipid) method to clean. up and EMR. Polish to salt out, separated on a Kinetex XB-C-18 with acetonitrile and 0.1% formic acid aqueous as eluant, and then detected by UFLC. MS/MS under positive (ESI+) electrospray ionization and MRM models. The average recoveries of 22 herbicides were in the range of 72% - 105% at the spiked level of 5, 10 and 20 mu g/kg. The relative standard deviations were less than 15%. In the method validation, correlation coefficients were higher than 0. 993 with the linear range from 1.0 mu g/L to 50 mu g/L. The qualitative analysis and quantitative analysis were investigated by UFLC. MS/MS and matrix. matched calibration curves. The results showed that EMR QuEChERS combined with UFLC. MS/MS purification method was rapid, accurate and sensitive for the determination of 22 triazine herbicides residues in corn.
What problem does this paper attempt to address?