TREATMENT COAL GASIFICATION WASTEWATER BY COMBINED BIOLOGICAL SYSTEM

Peng Xu,Hao Xu,Hongjun Han
2018-01-01
Fresenius environmental bulletin
Abstract:Coal gasification wastewater was treated by the novel combination process of hydrolytic acidification-AO. The effect of HRT and circle ratio on removal efficiency was investigated. Results indicated that the COD and total phenols removal efficiencies increased fast during start-up period with the influent concentrations were 1500 mg/L and 300 mg/L, respectively. Through the COD and total phenols removal efficiencies can be increased by prolonging the HRT from 6 h to 15 h, the optimal HRT of 10 h in hydrolytic acidification reactor was property, with the COD removal efficiency was 75-80%. Larger circle ratio can dilution the wastewater and reduce the inhibition effect posed by toxic and hazardous substances in influent. Reduced the circle ratio from 300% to 100%, the effluent COD and total phenols increased from 467.4 mg/L and 122.7 mg/L to 937.9 mg/L and 213.8 mg/L.
What problem does this paper attempt to address?