Abstract:The fuzzy mathematics was applied to get the illuminance index in departure lounge at Railway Station. Through the measurement of illumination in departure lounge at the railway stations in typical Chinese cities (Harbin, Beijing, Shanghai and Changsha), mean value of illuminance is calculated passengers' illumination comfort sense in departure lounge at four railway stations was investigated, statistical analysis of passengers' comfort sense under different levels of illuminance was carried out; the threshold of shading value was calculated. Illumination was further studied by means of Ridit method; and analysis the effect of illuminance to energy consumption The results show that the shading value annoying threshold of illuminance in departure lounge (EL) was 92.31x; meet the passengers comfort demand illuminance was chosen between 113.61x and 73.21x; and the illuminance which meets passengers comfort in departure lounge at the railway stations is 801x.Optimum lighting power density(LPD)is 2.08 W/m(2).