The difference of FTIR spectroscopic studies on normal and malignant tissues of lung

L Zhang,JS Wang,ZL Yang,YZ Xu,SF Weng,JS Shi,JG Wu
DOI: https://doi.org/10.3321/j.issn:0251-0790.2003.12.008
2003-01-01
Abstract:Fourier transform infrared spectroscopy (FTIR) was applied to study the malignant and normal tissues of lung. The distinct differences were observed in the FTIR spectra between the normal and malignant lung tissues. Amide II bands were weak in malignant tissues but strong in normal tissues; CH bending bands of malignant tissues around 1 460 cm(-1) became lower than those of normal tissues; the bands around 1 240 and 1 080 cm(-1), related to P-O and C-O stretching, respectively, both revealed different changes in malignant and normal tissues. The results also show that four groups of relative intensity ratios, including I-1 640/I-1 550, I-1 460/I-1 400, I-1 240/I-1 310 and I-1 080/I-1 160, were used to distinguish the normal and malignant tissues. The relative intensities of I-1 640/I-1 550 and I-1 080/I-1 160 of the malignant tissues were higher than that of the normal tissues; nevertheless those ratios of I-1 460/I-1 400, I-1 240/I-1 310 were lower in the malignant tissues. This might indicate that the FTIR spectroscopy can be used in the clinical diagnoses.
What problem does this paper attempt to address?