Acoustic Characterization of High Intensity Focused Ultrasound Field Generated from a Transmitter with Large Aperture

Tingbo Fan,Tao Chen,Wei Zhang,Jimin Hu,Yichuan Zhang,Dong Zhang
DOI: https://doi.org/10.1063/1.4977665
2017-01-01
AIP Conference Proceedings
Abstract:A combined experiment and simulation method was utilized to characterize the acoustic field generated from a strong focused HIFU transmitter. The nonlinear sound propagation was described by the spheroidal beam equation (SBE). The relationship between the source pressure amplitude and excitation voltage was determined by fitting the measured ratio of the second harmonic to the fundamental component of the focal waveform to the simulation result; then the acoustic pressure field generated by the strong focused transducer was predicted by using the SBE model. A commercial fiber optic probe hydrophone (FOPH) was utilized to measure the acoustic pressure field generated from a 1.1 MHz HIFU transmitter with a half aperture angle of 30 degrees. The validity of this combined approach was confirmed by the comparison between the measured results and the calculated ones. The results show that the current approach might be useful to describe the HIFU field.
What problem does this paper attempt to address?