Experience of monitoring the recurrent laryngeal nerve in thyroid surgery with endotracheal intubation

Feng Liang,Guifeng Liu,Huiying Li,Yunpengfei Li,Xuefeng Li
DOI: https://doi.org/10.1051/bioconf/20170801045
2017-01-01
BIO Web of Conferences
Abstract:Purpose: To analysis clinical experience of applying recurrent laryngeal monitoring endotracheal tube (NIM EMG Endotracheal Tube) in the surgery of thyroid. Method: A retrospective analysis of 84 patients who underwent endotracheal intubation laryngeal nerve monitoring by thyroid surgery in the Chinese-Japanese Friendship Hospital of Jilin University from March to December in 2015. To summarize the experience of intubation with NIM EMG Endotracheal Tube. Result 77 (91.7%) had initial intubation achievement in the 84 patients. FROM the 77 cases we had gotten s atisfactory nerve monitoring signal. Whereas there are 7 cases (8.3%) appear abnormal EMG or signal missing, in the 7 cases there is one which being intubated too deep ,3 cases which being intubated too shallow and 3 cases with malrotation intubation. Conclusion: We got the satisfactory signals after adjust(1)ing the tube by using the visual laryngoscope.
What problem does this paper attempt to address?