Ultra-sensitive and Multiplex Digital-Pcr for Quantifying the Mutants in Cell Free DNA by Employing Invasive Reaction As Identifier

Zheng Xiang,Bingjie Zou,Lixian Zhang,Xueping Ma,Xiemin Qi,Wei,Qinxin Song,Guohua Zhou
DOI: https://doi.org/10.1016/j.snb.2020.128362
2020-01-01
Abstract:Digital PCR (dPCR) is one of the most accurate and reliable tools for the examination of genetic alterations in liquid biopsy. The sensitivity of dPCR relies on the partition numbers for dPCR. The challenge is to achieve an ultra-sensitive dPCR without increasing the reaction units. Herein, we proposed the use of invasive reaction to pick up amplified mutants co-existing with a large amount of wild-type amplicons at each dPCR reaction unit (termed as Invader-dPCR). As invasive reaction is highly specific in one-base recognition, a 1000-fold sensitivity improvement for mutation detection was achieved in a conventional dPCR platform. As a result, the sample loading could be greatly increased without the increase of the number of dPCR reaction units. For cost-effective detection, we extended the Invader-dPCR to a "multiplex" detection model by using different signal-intensity groups to replace different dyes for identifying multiple targets, allowing the construction of a logic sensor to detect multiple mutants related to personalized medicine. The logic sensor was successfully used to guide the precise use of gefitinib by detecting 17 kinds of drug-sensitive and drug-resistant mutations simultaneously. Invader-dPCR was well validated for both the ultra-sensitive and multiplexed detection, and successfully applied to the detection of clinical samples.
What problem does this paper attempt to address?