Factors affecting 99Tcm-sulphur colloid internal mammary sentinel nodes lymphoscintigraphy

Min Zhou,Ying-jian Zhang,Jing-yi Cheng
2009-01-01
Abstract:Objective The aim of this study was to investigate the possible influential factors in 99Tcm-sulphur colloid (SC) internal mammary sentinel node (IMSN) lymphoscintigraphy. Methods IMSN lymphoscintigraphy data from 263 breast cancer patients with T1 or T2 tumors were retrospectively reviewed. Parameters including patients\u0027age, left or right breast, various quadrants, focus properties, o\u0027clock site around tumor of injection, injection volume, injection radioactivity and delay time of imaging were selected as influential factors to be analyzed by single factor and multifactor analyses with SPSS 11.5, significant value was P\u003c0.05. Results Left breast and inner half breast were easier to drain to internal mammary nodes (IMN) than that of right breast and outer haft breast (Wald=27.71, P\u003c0.05 and Wald=6.46, P\u003c 0.05). Peri-tumoral injection with three sites was better than with four sites (Wald=11.57, P=0.001). A better imaging quality was gained in 0.5×10-3 L per site. Radioactivity, age, location of injection, and delay time were insignificant to identify the IMSN. Conclusion Left breast and inner half breast, injection site, and injection volume are all independent factors affecting IMSN lymphoscintigraphy.\r\n\r\nKey words: \r\nBreat neoplasms;  Lymph nodes;  Tomography, emission-computed, single-photon;  Technetium Tc 99m sulfur colloid
What problem does this paper attempt to address?