Finite Element Analysis of the Low Calyx Urodynamics

Hu CHEN,Jian-sheng LAI,Guo-ping ZHAO,Guang-feng LONG,Dong-sheng ZHENG,Qiang XIA,Zhen-hua ZHAO
DOI: https://doi.org/10.3760/cma.j.issn.1674-4756.2009.13.013
2009-01-01
Abstract:Objective To evaluate the urodynamies of the low calyx which had the different anatomical features. Methods To creat the two dimensional digital modal of the collecting system being noncoaptive transportation and analyse the flow dynamic with the Automatic Dynamic Incremental Nonlinear Analysis System(ADINA). The maximum velocity(V) and the maximum pressure(P) in the pelvic and low calyx junction were test. Resnlts When the infundibulopelvic angle was 60 degrees, the length of the inferior calyx was 50 mm or the width of the inferior calyx was 3.6 nnn. It was found that the ve-locity and the pressure were less in the constant velocity perfusion trial and the velocity were also less in the constant pressure peffusion trial, but the pressure were more in the constant pressure perfusion. Conclusions The urine flow in the low calyx is the result of the potential energy and the upper urethral. It should be effected by the anatomical feature.
What problem does this paper attempt to address?