The selection of intraocular lens' refraction degree, for extremely high myopia extraction of cataract

YIN-Yue,YAN Xiao Ming
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2008.02.017
2008-01-01
Abstract:Objective To evaluate extremely high myopia patients before operations on how to define their intraocular lens(IOL)degrees can acquire the ideal refraction after operation.Method phacomulsification with IOL implantation was performed on 58 cases(94眼)with extremely high myopia(axial length≥28 mm)merging with cataract,a super voice emulsifying sufferer of the surgical operation will proceed review and analvsis of the operation followed by after visits.Result postoperatively,the uncorrected and corrected visual cuities were 0.5 or better,which were 60.6%;and 86.2% at three months respectively.Was examined by x2 P<0.05,the difference contains covariance meaning.There were 28 eyes among the axial Length that were 29 mms.corrected the sights better than 0.5 were 28 eyes,which was 100%.axial Length<29 mms and eye stalk>30 mms were examined by x2,the two groups show significant differences.P<0.005)Conclusion Before the surgical operation,precision measures the axial Length and cornea curvature in order to decrease IOL error margin.Also,should choose to report artificial crystal that appears to be in the range of middle to low degrees of myopic in the later process after the operation.